Description
Application Areas
- In aircraft hangars,
- In automobile factories,
- In healthcare-related laboratories and paint shops,
- In electrical and electronics laboratories,
- It can be applied in areas where flammable materials are stored or handled, even at low temperatures.
Application Information
Cleaned surfaces are primed with CLASS EPX-110. Within a maximum of 24 hours after the primer application, copper busbars are adhered to the floor—with a minimum of one unit in both x and y directions per 100 m²—and after ensuring physical contact with each other, CLASS EPX-150 is applied using a trowel and combed with a roller according to the specified consumption rate. After a 1-day interval, CLASS EPX-330 is applied using a trowel, deaerated with a spiked roller to remove gas bubbles, and left to dry.
Consumption
1.5 kg for 1 mm thickness.
Packaging
A/B: 16.4 + 3.6 = 20 kg set